Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
J AAPOS ; 28(1): 103801, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38211831

RESUMO

PURPOSE: To present the results of a pilot study of microvascular flow imaging (MFI) in characterizing tumor vasculature of retinoblastoma. METHODS: The medical records of consecutive patients with retinoblastoma presenting at our institution between July 2019 and June 2022 that were imaged using MFI were reviewed retroactively. Each patient underwent diagnostic evaluation according to standard of care by examination under anesthesia with fluorescein angiography and ocular ultrasound imaging, including color Doppler and MFI. RESULTS: Thirteen eyes of 10 patients with retinoblastoma were included. MFI showed a prominent feeder vessel in 8 eyes, basket vasculature in 6 eyes and tumor bed vascularity in 10 eyes. MFI showed a more extensive vascular branching pattern that was not visible on color Doppler and fluorescein angiography in all eyes. CONCLUSIONS: MFI of retinoblastoma patients could add information about tumor vascularity not detectable by color Doppler or fluorescein angiography. Further study is needed to determine whether this information could be used to predict prognosis for ocular salvage and tumor response to treatment.


Assuntos
Neoplasias da Retina , Retinoblastoma , Humanos , Retinoblastoma/diagnóstico por imagem , Retinoblastoma/patologia , Projetos Piloto , Angiofluoresceinografia , Ultrassonografia , Neoplasias da Retina/diagnóstico por imagem , Neoplasias da Retina/patologia
2.
Ophthalmic Surg Lasers Imaging Retina ; 55(3): 136-140, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38270567

RESUMO

BACKGROUND AND OBJECTIVE: Monitoring the response of retinoblastoma to globe-salvaging therapies is based on subjective assessments of changes determined by fundoscopy, ultrasound, and optical coherence tomography. Advances in organ-preserving therapies have increased the need for objective, quantitative estimates of tumor response to treatment. Primary tumor volume is a metric that can be objectively determined as a surrogate measure of treatment response. PATIENTS AND METHODS: We evaluated the correlation of objective, quantitative estimates of tumor volume made with two-dimensional (2D) and three-dimensional (3D) ultrasound with gold standard pathological tumor volumes derived by analysis of enucleation specimens. RESULTS: Twelve eyes in 12 patients undergoing primary enucleation were evaluated by 2D and 3D ultrasound during ophthalmic examination under anesthesia prior to enucleation. 2D- and 3D-ultra-sound measurements of tumor volume were both strongly correlated with pathological estimates of tumor volume (r = 0.69, P = 0.018; and r = 0.66, P = 0.027, respectively). CONCLUSIONS: 2D- and 3D-ultrasound measurements of retinoblastoma primary tumor volume are highly correlated with pathological estimates. 3D measurements are easy to perform with volumetric probes and consider the irregular morphology of the tumor. Further study should be undertaken to evaluate the performance of these metrics as surrogate markers of tumor response to treatment. [Ophthalmic Surg Lasers Imaging Retina 2024;55:136-140.].


Assuntos
Neoplasias da Retina , Retinoblastoma , Humanos , Retinoblastoma/diagnóstico por imagem , Retinoblastoma/cirurgia , Ultrassonografia/métodos , Neoplasias da Retina/diagnóstico , Neoplasias da Retina/patologia , Imageamento Tridimensional/métodos
4.
Am J Epidemiol ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37946325

RESUMO

There's a paucity of robust normal fractional limb and organ volume standards from a large and diverse ethnic population. The Fetal 3D Study was designed to develop research and clinical applications for fetal soft tissue and organ volume assessment. The NICHD Fetal Growth Studies (2009-2013) collected 2D and 3D fetal volumes. In the Fetal 3D Study (2015-2019), sonographers performed longitudinal 2D and 3D measurements for specific fetal anatomic structures in research ultrasounds of singletons and dichorionic twins. The primary aim was to establish standards for fetal body composition and organ volumes, overall and by maternal race/ethnicity, and determine if these standards vary for twins versus singletons. We describe study design, methods and details about reviewer training. Basic characteristics of this cohort, with their corresponding distributions of fetal 3D measurements by anatomic structure, are summarized. This investigation is responsive to critical data gaps in understanding serial changes in fetal subcutaneous fat, lean body mass and organ volume in association with pregnancy complications. In the future, this cohort can answer critical questions regarding the potential influence of maternal characteristics, lifestyle factors, nutrition, and biomarker and chemical data on longitudinal measures of fetal subcutaneous fat, lean body mass and organ volumes.

5.
Pediatr Radiol ; 53(10): 2144-2148, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37423914

RESUMO

We describe prenatal diagnosis of Poland-Möbius syndrome using a combination of ultrasound and MRI. Poland syndrome was diagnosed based on absence of the pectoralis muscles associated with dextroposition of the fetal heart and elevation of the left diaphragm. Associated brain anomalies that led to the diagnosis of Poland-Möbius syndrome, included ventriculomegaly, hypoplastic cerebellum, tectal beaking, and a peculiar flattening of the posterior aspect of the pons and medulla oblongata, which has been reported by postnatal diffusion tensor imaging studies as a reliable neuroimaging marker for Möbius syndrome. Since abnormalities of cranial nerves VI and VII may be difficult to detect prenatally, careful attention to the appearance of the brain stem as illustrated in the current report may aid in the prenatal diagnosis of Möbius syndrome.


Assuntos
Síndrome de Möbius , Síndrome de Poland , Feminino , Humanos , Gravidez , Imagem de Tensor de Difusão , Síndrome de Möbius/diagnóstico por imagem , Síndrome de Poland/diagnóstico por imagem , Diagnóstico Pré-Natal
6.
Children (Basel) ; 10(6)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37371247

RESUMO

BACKGROUND: Ultrasonography (US) is the first-line diagnostic tool used to assess fetal musculoskeletal (MSK) anomalies. Associated anomalies in other organ systems may benefit from evaluation via Magnetic Resonance Imaging (MRI). In this study, we compared the diagnostic accuracy of US and MRI to diagnose fetal MSK (primary objective) and non-MSK anomalies (secondary objective). We describe additional findings by low-dose computerized tomography (CT) in two cases incompletely characterized via US and MRI. MATERIALS AND METHODS: This was an IRB-approved retrospective study of consecutive patients with suspected fetal MSK anomalies examined between December 2015 and June 2020. We compared individual MSK and non-MSK anomalies identified via US, MRI, and CT with postnatal outcomes. Sensitivity and specificity for US and MRI were calculated and compared. RESULTS: A total of 31 patients with 112 MSK and 43 non-MSK anomalies were included. The sensitivity of MRI and US for MSK anomalies was not significantly different (76.6% vs. 61.3%, p = 0.3). Low-dose CT identified eight additional skeletal anomalies. MRI diagnosed a higher number of non-MSK anomalies compared to US (81.4% vs. 37.2%, p < 0.05). CONCLUSIONS: Fetal MRI and US have comparable sensitivity for MSK anomalies. In selected cases, low-dose CT may provide additional information. Fetal MRI detected a larger number of non-MSK anomalies in other organ systems compared to US. Multimodality imaging combining all the information provided by MRI, US, and CT, if necessary, ultimately achieved a sensitivity of 89.2% (95% CI: 83.4% to 95.0%) for the diagnosis of musculoskeletal anomalies and 81.4% for additional anomalies in other organs and systems.

7.
World J Orthop ; 14(3): 155-165, 2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36998387

RESUMO

BACKGROUND: Congenital transverse deficiencies are horizontal deficiencies of the long bones that occur with a reported incidence as high 0.38%. They can occur alone or represent a manifestation of a various clinical syndromes. Diagnosis has traditionally comprised of conventional radiography and prenatal imaging studies. There has been much advancement regarding prenatal imaging modalities to allow for early diagnosis and appropriate treatment. AIM: To summarize the current state of knowledge on congenital transverse limb deficiencies and to provide an update regarding the radiographic evaluation of congenital transverse limb deficiencies. METHODS: This IRB-exempt scoping review followed the PRISMA-ScR checklist for scoping reviews strictly. Five search engines were searched for a total of 265 publications. Four authors reviewed these during the screening process. Of these, 51 studies were included in our article. Prenatal magnetic resonance imaging (MRI), 3D Ultrasound, and multidetector Computed tomography (CT) exist are emerging modalities that have the potential to improve diagnosis. RESULTS: Use of the appropriate classification system, three-dimensional ultrasonography with a maximum intensity projection, and appropriate use of prenatal MRI and prenatal CT can improve diagnosis and inter-provider communication. CONCLUSION: Further scholarly efforts are required to develop improve standardized guidelines regarding the pre-natal radiographic evaluation of congenital limb deficiencies.

8.
J Clin Lab Anal ; 37(4): e24854, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36843202

RESUMO

BACKGROUND: Renal medullary carcinoma (RMC) is a diagnostically challenging, aggressive primary renal malignancy associated with abysmal survival. Delays in diagnosis contribute to most patients having diffusely metastatic disease at the time of initial presentation. METHODS: We present the case of a 13-year-old African American male with sickle cell trait who presented with a renal mass and hematuria. Evaluation included imaging, fluid cultures, and cytologic assessment. RESULTS: Patient was diagnosed with RMC based on cytologic assessment of sub-centimeter fluid collections aspirated from the left kidney at the time of cortical biopsy for suspected renal mass. The additional fluid aspiration in conjunction with renal biopsy was an atypical but crucial step in early diagnosis. CONCLUSION: Cytomorphologic evaluation of fluid biospecimens is not currently part of the standard work-up for patients with renal masses but, when available, can provide crucial information that reduces time to diagnosis. Prompt symptom recognition and treatment initiation may improve patient outcomes.


Assuntos
Carcinoma Medular , Carcinoma de Células Renais , Neoplasias Renais , Humanos , Masculino , Adolescente , Carcinoma Medular/diagnóstico , Carcinoma Medular/patologia , Carcinoma Medular/terapia , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Rim/diagnóstico por imagem , Rim/patologia , Biópsia
9.
Pediatr Radiol ; 53(2): 198-209, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198870

RESUMO

BACKGROUND: Fetal cardiac magnetic resonance imaging (MRI) requires high spatial and temporal resolution and robustness to random fetal motion to capture the dynamics of the beating fetal heart. Slice-to-volume reconstruction techniques can produce high-resolution isotropic images while compensating for random fetal motion. OBJECTIVE: The objective of this study was to evaluate image quality for slice-to-volume reconstruction of four-dimensional balanced steady-state free precession (bSSFP) imaging of the fetal heart. MATERIALS AND METHODS: A cohort of 13 women carrying fetuses with congenital heart disease were imaged with real-time bSSFP sequences. Real-time bSSFP sequences were post-processed using a slice-to-volume reconstruction algorithm to produce retrospectively gated 4-D sequences with isotropic spatial resolution. Two radiologists evaluated slice-to-volume reconstruction image quality on a scale from 0 to 4 using 11 categories based on a segmental approach to defining cardiac anatomy and pathology. A score of 0 corresponded to cardiac structures not visualized at all and four corresponded to high quality and distinct appearance of structures. RESULTS: In 11 out of 13 cases, the average radiologist score of image quality across all categories was 3.0 or greater. In the remaining two cases, slice-to-volume reconstruction was not possible due to insufficient image quality in the acquisition. CONCLUSION: Slice-to-volume reconstruction has the potential to produce isotropic images with high spatial and temporal resolution that can display the anatomy of the fetal heart in arbitrary imaging planes retrospectively. More rapid, motion-robust acquisitions may be necessary to successfully reconstruct the fetal heart in all patients.


Assuntos
Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Humanos , Feminino , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Coração , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Feto , Coração Fetal/diagnóstico por imagem , Coração Fetal/patologia
10.
Waste Manag ; 154: 232-244, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36274433

RESUMO

The main focus of this work is to study the processability and characteristics of highly loaded spent coffee grounds (SCG) thermoplastic polymer composites, for sustainable applications. SCG powder was characterized in terms of size distribution, moisture, morphology and thermal stability. Polymer/SCG composites were prepared by extrusion compounding. Polypropylene (PP) homopolymer and copolymer were used as the polymeric matrix. Upon compounding by extrusion composites were injection moulded and characterized for its physical, morphological and mechanical properties in order to determine the effect of polymer type and filler content. Morphological characteristics of the composites were investigated using optical microscopy and SEM analysis. The results for PP homopolymer showed little deterioration of the mechanical properties when using the highest SCG load. In the case of PP homopolymer, the greatest variations occurred when increasing from 0 to 20 %. With higher SCG loads, the measured properties changed little. PP copolymer showed a more continuous pattern of properties decay with increasing SCG load, especially for tensile strength, elongation at break and impact strength. Regarding PP copolymer, with maximum SCG load, the tensile strength decreased from 26.8 GPa (neat PP) to 10.8 GPa, the elongation at break showed a drop of more than 95 %, while the Young's modulus increased from 800 MPa to 1160 MPa. This research work has shown that SCG can be used as fillers in the preparation of environmentally friendly composites with SCG load up to 60 wt% thus contributing to the reuse of waste generated by the coffee industry.

11.
Cureus ; 14(7): e27469, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36060334

RESUMO

Os subfibulare is an accessory ossicle of the lateral malleolus at the distal end of the fibula. In most instances, os subfibulare is found incidentally on radiographs. While os subfibulare typically remains asymptomatic, some cases may present with ankle pain or instability. To initiate appropriate treatment and maximize patient outcomes, it is crucial to accurately visualize the accessory ossicle. Here, we report a symptomatic case of os subfibulare diagnosed with ankle radiographs and a 3D water selective cartilage scan (3D_WATSc, Ingenia, Philips Healthcare, The Netherlands) magnetic resonance imaging sequence and treated surgically with open ossicle excision and a modified Broström procedure.

12.
Clin Perinatol ; 49(3): 751-770, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36113933

RESUMO

Imaging plays an important role in evaluating patients with suspected intrauterine and perinatal infections. Advances in fetal imaging including both ultrasound and MRI allow for increasingly more specific diagnosis if the radiologist is familiar with specific imaging features and patterns. Early imaging of neonates with suspected central nervous system infection is valuable to enable prompt treatment and differentiate infection from other conditions which can clinically present similarly. Ultrasound is a useful initial modality to screen for abnormalities however MRI with and without contrast remains the optimal examination to characterize infection, evaluate for potential surgical targets, and provide prognostic information.


Assuntos
Doenças do Recém-Nascido , Diagnóstico Pré-Natal , Feminino , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Gravidez , Diagnóstico Pré-Natal/métodos , Ultrassonografia
13.
J Matern Fetal Neonatal Med ; 35(25): 9770-9779, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35341439

RESUMO

OBJECTIVE: To describe the characteristics of amniotic fluid sludge obtained from patients in term and preterm gestations. METHODS: This cross-sectional study included patients with dense aggregates of particulate matter detected in amniotic fluid, observed with transvaginal sonography. All patients were in labor and had an impending delivery, either preterm or at term. Echogenic material contained within amniotic fluid was retrieved transvaginally by needle amniotomy under direct visualization. The amniotic fluid analysis consisted of a Gram stain, cultures for aerobic/anaerobic bacteria and genital mycoplasmas, and a white blood cell count. RESULTS: Twenty-five patients ranging from 18 to 41 weeks of gestation were included in the study. We observed the following: (1) the appearance of amniotic fluid was consistent with pus-like material, vernix, or meconium by naked eye examination; (2) samples collected before 33 weeks of gestation (n = 13) had a pus-like appearance; however, after this gestational age, most of the samples [83% (10/12)] appeared to be consistent with vernix; (3) amniotic fluid cultures were positive for microorganisms in 13 patients, of which 10 were preterm gestations before 33 weeks; (4) the most frequent microorganisms retrieved by culture were genital mycoplasmas (Ureaplasma urealyticum [46% (6/13)]), followed by Mycoplasma hominis [31% (4/13)] and Candida albicans [15% (2/13)]; and (5) patients with sonographic particulate matter in preterm gestations frequently presented acute histologic chorioamnionitis and funisitis, but these conditions were rare in patients at term. CONCLUSION: The nature of amniotic fluid particulate material varies as a function of gestational age. The material obtained in preterm gestations is frequently related to an inflammatory process, while that obtained at term is often consistent with vernix and appears to represent a maturational process.


Assuntos
Corioamnionite , Complicações Infecciosas na Gravidez , Gravidez , Recém-Nascido , Feminino , Humanos , Líquido Amniótico/diagnóstico por imagem , Líquido Amniótico/microbiologia , Esgotos , Amniocentese , Estudos Transversais , Complicações Infecciosas na Gravidez/diagnóstico , Corioamnionite/diagnóstico , Corioamnionite/microbiologia , Material Particulado , Supuração
14.
J Matern Fetal Neonatal Med ; 35(25): 9765-9769, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35337237

RESUMO

OBJECTIVE: Comprehensive fetal care centers address congenital anomalies by developing pre- and post-natal care plans in a multidisciplinary format. To reduce exposure during the Coronavirus Infectious Disease-2019 (COVID-19) pandemic, the Centers for Medicare & Medicaid Services (CMS) broadened access to telehealth services. We assessed provider satisfaction with the rapid transition from in-person prenatal visits to multidisciplinary consultations via telehealth as an adaptive response to the pandemic. METHODS: Patients referred to an urban academic fetal care center during the first 6 weeks of the COVID-19 pandemic underwent advanced imaging including fetal MRI, focused ultrasound, and fetal echocardiography. Subsequently, multidisciplinary telehealth consultations occurred with all providers attending virtually. Patients were given the option of attending the multidisciplinary telehealth consultation in a conference room in the hospital or from home. During these meetings, relevant images were reviewed with all participants via screen sharing through a secure video platform. Provider satisfaction with the telehealth paradigm was assessed using an electronic survey. RESULTS: Twenty-two surveys were administered with a response rate of 82%. 89% of providers were highly satisfied with the telehealth format. 72% of providers would prefer the multidisciplinary telehealth format to an in-person visit for future visits after COVID-19 restrictions are lifted. 22% of providers would leave the choice to the patient's family. One provider preferred in-person visits. Some providers noted that virtual conferences limited the ability to draw pictures, show educational materials, and provide emotional support. CONCLUSION: Providers were overwhelmingly supportive of continuing multidisciplinary telehealth conferences for complex prenatal consultations, even after restrictions are lifted, which has led to the continuation of this model for the duration of the pandemic. Providers highlighted the convenience and improved care coordination across specialties. Further studies to examine the patient experience with virtual consultations are warranted.


Assuntos
COVID-19 , Doenças Transmissíveis , Telemedicina , Idoso , Gravidez , Feminino , Humanos , Estados Unidos , Pandemias , Satisfação Pessoal , Satisfação do Paciente , Medicare , Telemedicina/métodos , Cuidado Pré-Natal/métodos , Encaminhamento e Consulta
15.
Pediatr Radiol ; 52(3): 513-526, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34842935

RESUMO

BACKGROUND: Increasing evidence supports an association among congenital heart disease (CHD), structural brain lesions on neuroimaging, and increased risk of neurodevelopmental delay and other structural anomalies. Fetal MRI has been found to be effective in demonstrating fetal structural and developmental abnormalities. OBJECTIVE: To determine the contribution of fetal MRI to identifying cardiovascular and non-cardiovascular anomalies in fetuses with CHD compared to prenatal US and fetal echocardiography. MATERIALS AND METHODS: We performed a retrospective study of fetuses with CHD identified by fetal echocardiography. Exams were performed on 1.5-tesla (T) or 3-T magnets using a balanced turbo field echo sequence triggered by an external electrocardiogram simulator with a fixed heart rate of 140 beats per minute (bpm). Fetal echocardiography was performed by pediatric cardiologists and detailed obstetrical US by maternal-fetal medicine specialists prior to referral to MRI. We compared the sensitivity of fetal MRI and fetal echocardiography for the diagnosis of cardiovascular anomalies, as well as the sensitivity of fetal MRI and referral US for the diagnosis of non-cardiac anomalies. We performed statistical analysis using the McNemar test. RESULTS: We identified 121 anomalies in 31 fetuses. Of these, 73 (60.3%) were cardiovascular and 48 (39.7%) involved other organ systems. Fetal echocardiography was more sensitive for diagnosing cardiovascular anomalies compared to fetal MRI, but the difference was not statistically significant (85.9%, 95% confidence interval [CI] 77.8-94.0% vs. 77.5%, 95% CI 67.7-87.2%, respectively; McNemar test 2.29; P=0.13). The sensitivity of fetal MRI was higher for diagnosing extracardiac anomalies when compared to referral US (84.1%, 95% CI 73.3-94.9% vs. 31.8%, 95% CI 18.1-45.6%, respectively; McNemar test 12.9; P<0.001). The additional information provided by fetal MRI changed prognosis, counseling or management for 10/31 fetuses (32.2%), all in the group of 19 fetuses with anomalies in other organs and systems besides CHD. CONCLUSION: Fetal MRI performed in a population of fetuses with CHD provided additional information that altered prognosis, counseling or management in approximately one-third of the fetuses, mainly by identifying previously unknown anomalies in other organs and systems.


Assuntos
Cardiopatias Congênitas , Diagnóstico Pré-Natal , Criança , Feminino , Coração Fetal , Feto/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Gravidez , Diagnóstico Pré-Natal/métodos , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos
17.
Pediatr Radiol ; 52(4): 716-722, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34633478

RESUMO

Upper gastrointestinal series is considered the gold standard imaging test to evaluate for malrotation and midgut volvulus. US has been explored for this purpose in recent years and has been shown to be a good alternative because of its relatively good accuracy, fast learning curve for sonographers and radiologists, as well as convenience for children, clinical staff and radiologists in the neonatal intensive care unit. In this article we describe our experience and review the evidence supporting the use of emergency US primarily to diagnose midgut volvulus as well as its use as a problem-solving tool for the diagnosis of malrotation. The examination technique, normal and abnormal findings are described, with emphasis on the whirlpool and superior mesenteric artery cutoff signs to diagnose midgut volvulus.


Assuntos
Volvo Intestinal , Criança , Diagnóstico por Imagem , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Volvo Intestinal/diagnóstico por imagem , Radiologistas , Ultrassonografia/métodos
18.
J Magn Reson Imaging ; 54(4): 1349-1360, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33949725

RESUMO

BACKGROUND: Super-resolution is a promising technique to create isotropic image volumes from stacks of two-dimensional (2D) motion-corrupted images in fetal magnetic resonance imaging (MRI). PURPOSE: To determine an acquisition quality metric and correlate that metric with radiologist perception of three-dimensional (3D) image quality. STUDY TYPE: Retrospective. SUBJECTS: Eighty-seven patients, mean gestational age 29 ± 6 weeks. FIELD STRENGTH/SEQUENCE: 1.5 T/2D fast spin-echo. ASSESSMENT: Four radiologists (L.G., D.M.E.B., P.C., and J.V.; 31, 21, 7, and 7 years' experience, respectively) graded reconstructions on a 0 to 4 scale for overall appearance and visibility of specific anatomy. During reconstruction, slices were labeled as inliers based on correlation between a simulated vs. actual acquisition. The fraction of brain voxels in inlier slicers vs. total brain voxels was measured for each acquisition. STATISTICAL TESTS: Paired sample t test, Pearson's correlation, intra-class correlation. RESULTS: The average brain mask inlier fraction for all acquisitions was 0.8. There was a statistically significant correlation (0.71) between overall reconstruction appearance and number of acquisitions with inlier fraction above 0.73. There was low correlation (0.21, P = 0.05) between the number of acquisitions used in the reconstruction and overall score when no data quality measure was considered. Similar results were found for ratings of specific anatomy. Statistically significant differences in overall perception of image quality were found when using three vs. four, four vs. five, and three vs. five high-quality acquisitions in the reconstruction. Five high-quality acquisitions were sufficient to yield an average radiologist rating of 3.59 out of 4.0 for overall image quality. DATA CONCLUSION: Reconstruction quality can be reliably predicted using the brain mask inlier fraction. Real-time super-resolution protocols could exploit this to terminate acquisition when enough high-quality acquisitions have been collected. To achieve consistent 3D image quality it may be necessary to acquire more than five scans to compensate for severely motion-corrupted acquisitions. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: 1.


Assuntos
Confiabilidade dos Dados , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Lactente , Estudos Retrospectivos
19.
Clin Imaging ; 78: 121-126, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33774578

RESUMO

Retinoblastoma is the prototypic genetic tumor. Caused by mutations in the RB1 gene, retinoblastomas are heritable in 40% of the cases and, in such cases, tumors are bilateral in 80%, unilateral in 15%, and trilateral in 5% of the cases. Trilateral retinoblastoma is a term that describes bilateral retinoblastomas plus a midline suprasellar or pineal neuroectodermal tumor. Patients with a germline RB1 mutation have 45% chance of having an offspring with retinoblastoma. Prenatal diagnosis is important because the doubling time is fast, ranging from 7 to 15 days. Thus, late diagnosis during infancy is associated with larger tumors and increased risk of death, need for globe enucleation and vision loss. We report a case of bilateral retinoblastomas diagnosed by targeted high-resolution ultrasonography of the orbits at 32 weeks of gestation in a patient at risk. This report demonstrates the feasibility of accurately detecting even tiny retinoblastomas by ultrasound with current technology. We also review prenatally published cases to date and comment on the technical strengths and limitations of ultrasound and fetal MRI for prenatal diagnosis of retinoblastomas.


Assuntos
Glândula Pineal , Neoplasias da Retina , Retinoblastoma , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Gravidez , Diagnóstico Pré-Natal , Neoplasias da Retina/diagnóstico por imagem , Neoplasias da Retina/cirurgia , Retinoblastoma/diagnóstico por imagem , Retinoblastoma/cirurgia
20.
Clin Imaging ; 78: 45-50, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33756309

RESUMO

We present a case of Klippel-Feil Syndrome, a congenital skeletal defect where multiple cervical vertebral bodies are fused. Klippel-Feil Syndrome has multiple associated anomalies, with a notable one being Sprengel's deformity. In this case, the patient was given a diagnosis of Klippel-Feil Syndrome prenatally after suspected cervical vertebrae fusion and Sprengel's deformity were seen on both fetal magnetic resonance imaging (MRI) and ultrasound. Prenatal diagnosis of Sprengel's deformity has been reported once in the literature. In this report, we present imaging findings of Sprengel's deformity seen in association with Klippel-Feil Syndrome using a combination of fetal ultrasound and MRI.


Assuntos
Síndrome de Klippel-Feil , Articulação do Ombro , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Síndrome de Klippel-Feil/complicações , Síndrome de Klippel-Feil/diagnóstico por imagem , Gravidez , Escápula/diagnóstico por imagem , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...